RS2000 SUM NG Solenoid Driver Compliant
More information about Data Capture by clicking on “Contact Us” and
downloading the PDF with the technical specifications.
Related Products:
![cas-captacao-dados](https://catalogo.castecnologia.com.br/wp-content/uploads/2018/04/cas-captacao-dados@3x-300x300.png)
Data Capture
4BAND
ref. 101.0026.00
RS2000 SUM NG
Solenoid Driver Compliant
![cas-captacao-dados](https://catalogo.castecnologia.com.br/wp-content/uploads/2018/04/cas-captacao-dados@3x.png)
Data Capture
4BAND
ref. 101.0026.00
More information about Data Capture by clicking on “Contact Us” and
downloading the PDF with the technical specifications.
Related Products:
Technical Specification
- Network: Not Applied
- Serial Communication: EIA-485 / RS-485 for Communication – Optical Gate for Local Configuration
- Input/Output Port:
• 4 Logical Seal Sensor
• 4 Activation of the shut-off valve.
• 4 Pulse counters. - Connector A: Female RJ12 for Pulse Receiving / Activation of the shut-off valve.
- Connector B: 2 Way Connector Block for Power Supply Input
- Connector C: 3 Way Connector Block for Communication
- Average Power Consumption: 1,2W
- Power supply: 24VCC
- Operating temperature: 0ºC to +50ºC
- Dimensions: 117,5 x 88,5 x 46mm
- Weight: 150g
- IP Code: IP50W
Technical Drawing