RS2000 Standard 3G

Remote Terminal Unit with mobile 3G technology.

Used for various data acquisition, with successful applications in e-Power and Transparent Communication (Bridge).

Its RS-485 interfaces and its Inputs enable applications for industrial automation.

Features:

  • Sensors for outage detection in the electrical network.
  • Sensors with tampering applications, open collector outputs and a relay output for triggering external devices only for remote control version.
  • Requires use of external antenna via TNC connector.

Related Products:

Remote Terminal Unit
RS2000
cod. 100.0148.00
(Without Telecontrol)

Remote Terminal Unit
RS2000
cod. 100.0148.50
(With Telecontrol)


I want to be contacted

RS2000 Standard 3G

cas-modulo-comunicacao@3x

Remote Terminal Unit
RS2000
cdd. 100.0148.00 (Without Telecontrol)

cas-modulo-comunicacao@3x

Remote Terminal Unit
RS2000
cod. 100.0148.50 (With Telecontrol)

Remote Terminal Unit with mobile 3G technology.

Used for various data acquisition, with successful applications in e-Power and Transparent Communication (Bridge).

Its RS-485 interfaces and its Inputs enable applications for industrial automation.

Features:

  • Sensors for outage detection in the electrical network.
  • Sensors with tampering applications, open collector outputs and a relay output for triggering external devices only for remote control version.
  • Requires use of external antenna via TNC connector.


I want to be contacted

Related Products:

Technical Specification

  • Network:
    • GSM 800/900/1800/1900MHz
    • GSM GPRS/EDGE/SMS/HCSD
  • Serial Communication:
    • RS232 – Programmable Speed from 300 to 115200bps
    • RS232 – Local Configuration to 4800bps
    • RS485 – With Support to MODBUS/RTU Devices
  • Input/Output Port:
    • 5 Digital Input with Optical Coupler – DC(3) and AC (2)
    • 3 Digital Input/Output
    • 2 A/D Inputs
    • 3 Open Collector Outputs
    • 1 Relay Output – 15A
  • Connector A: Male DB9
  • Connector B: Female DB9
  • Connector C: TNC – Antenna RF
  • Connector E: 3 Way Terminal Block – Serial Interface EIA-485 Standard
  • Connector F: 22 Way Terminal Block – Input/Output Ports
  • Connector G: 2 Way Terminal Block – Power Supply Output
  • Connector H: 3 Way Terminal Block – Power Supply Input
  • Telecontrole:
    • Not Applied (COD. 100.0014.00)
    • Relay 1C 10A 120VCA Internal (COD. 100.0014.01)
  • Average Power Consumption: 4W
  • Power Supply: 65~280VCA (L+N+Earth) or 10~30VCC
  • Operating Temperature: -4ºF to +158ºF
  • Dimension: 134 x 101 x 52mm
  • Weight: 460g
  • IP Code: IP50W

Technical Drawing